Results and limits

What Arvon has been tested on, how it was tested, and what has not been shown yet. Every number below comes with its scope: the organism, the organoid type, how long the organoids were imaged, and how far ahead the prediction was made.

Fish retinal organoids

Scope: medaka (fish) retinal organoids from one lab (Afting et al., PLOS Biology 2026, public data, CC BY 4.0). 987 organoids in 11 experiments, imaged every 30 minutes for 72 hours. The outcome, pigmented retina (RPE) or lens present at the end of culture, was scored about 72 hours after the first image. The authors had segmented and masked the images with their own model before publishing them.

PredictionFrom images up toROC-AUC [95% CI]Notes
RPE at the end of culture12 hours0.86 [0.80 to 0.90]About 60 hours before the outcome was scored, and about 30 hours before RPE is visible by eye. Before 8 hours, nothing beats chance.
Lens at the end of culture8 hours0.86 (median within single experiments; range 0.64 to 0.97)Lens rates differ a lot between experiments, which inflates numbers pooled across them, so we report the within-experiment value.
Line charts of ROC-AUC against hours of images used, for RPE and lens. Both are near chance at the start and rise to about 0.85 by 8 to 12 hours.
ROC-AUC against how many hours of images are used. Shaded bands: 95% confidence intervals from resampling experiments.

Calls with honest uncertainty

Each organoid is called likely to fail, likely to succeed, or uncertain (split conformal prediction with a 90% target). On held-out experiments, the real outcome was covered by the call 89 to 94% of the time. From 12 hours, the model commits on about two thirds of organoids and is right 85 to 87% of the time when it does. Earlier it mostly says uncertain, which is the honest answer when the images don't yet carry the information.

Line charts showing coverage close to 0.9 at every decision time, the share of uncertain calls falling after 8 to 12 hours, and accuracy of committed calls around 0.85 from 12 hours.
Coverage, share of uncertain calls, and accuracy of committed calls at each decision time, fish retinal organoids, measured on held-out experiments.

What a lab would have seen

Treating this public data as if a lab had sent it, the retrospective report found that at the strictest alert setting 73% of organoids that ended without RPE would have been flagged, typically 48 hours before the outcome was scored, while 15% of good organoids would have been flagged by mistake. That alert setting was chosen on the same data, so these two numbers are slightly optimistic. See the one-page summary (PDF).

The data trust check across datasets

Before trusting any accuracy number, Arvon asks whether a model could get it without looking at the organoids at all: from file details, from the empty background or the image border, from the very first image, or from which group an organoid belongs to. It also checks whether accuracy holds when whole groups are held out. On public data it flagged two human datasets as untrustworthy for forecasting, and we treat them that way.

Grid of check results for five dataset and outcome pairs. The fish retinal rows mostly pass. The human brain and V3Cell rows show warnings and failures, including grouped validation failures.
Each cell is a model that sees only one kind of input, with its ROC-AUC. Green passes, amber is a warning, red is a failure.
  • Human amniotic-sac organoids (V3Cell, 48 h): the preregistered test looked excellent, but fate could be predicted from the background around each organoid and from the very first frame. The fate groups were most likely imaged under different conditions, so this is not evidence of forecasting.
  • Human cerebral organoids (4 cell-line clones, images days 2 to 25, size at day 30): the clone alone predicts final size. The images add little beyond the clone until 8 to 14 days before the end.

How it was tested

  • Nested cross-validation: each experiment is held out in turn, and every modelling choice is made using only the other experiments. No organoid or experiment is ever used to predict itself.
  • Only images taken up to the decision time are used. Later images cannot change an earlier prediction, and this is tested.
  • Confidence intervals come from resampling whole experiments, not single organoids.
  • The evaluation pipeline is now frozen and preregistered: its code and settings are fingerprinted, and any new dataset goes through it unchanged. Changes have to be logged as deviations. The fish results above were produced before the freeze, with the same nested method.

What has not been shown yet

  • Outcome prediction on human organoids. Validation is in progress on public human data, and we are looking for labs to run pilots on their own experiments.
  • Predictions weeks ahead. The longest outcome horizon tested so far is about 72 hours.
  • Performance on raw images from another lab's microscopes and protocols. The fish images had been segmented by their authors.
  • Performance in a prospective study, as opposed to looking back at finished experiments.

If you have finished experiments with early images and known outcomes, a pilot is the fastest way to find out whether this works for your organoids. Request a pilot.